50 KLD STP Plant in Chennai
RRR ENVIRO SYSTEMS provides 50 KLD Sewage Treatment Plant solutions for residential, commercial, institutional, hospitality and other suitable wastewater treatment applications in Chennai, Tamil Nadu.
We support STP process selection, engineering, equipment supply, installation, commissioning, maintenance and upgradation according to project requirements.
50 KLD STP – Quick Information
- Nominal Capacity: 50 KLD
- Approx. Treatment: 50,000 L/day
- Average Flow: approx. 2.08 m³/hr
- Domestic Sewage Treatment
- Primary & Biological Treatment
- Secondary Solid Separation
- Tertiary Treatment Options
- Disinfection & Reuse Options
50 KLD Sewage Treatment Plant in Chennai
A 50 KLD STP Plant in Chennai is designed for a nominal sewage treatment capacity of approximately 50,000 litres per day.
The average flow corresponding to 50 KLD is approximately 2.08 m³/hr when averaged over 24 hours. Actual hydraulic design must also consider peak flow, infiltration, operating hours and site-specific sewage generation.
RRR ENVIRO SYSTEMS provides project-specific sewage treatment solutions for suitable requirements across Chennai and Tamil Nadu.
50 KLD STP Basic Details
- ✓ Nominal Capacity – 50 KLD
- ✓ Daily Flow – 50,000 Litres/Day
- ✓ Average Flow – approx. 2.08 m³/hr
- ✓ Screening & Preliminary Treatment
- ✓ Biological Treatment
- ✓ Clarification / Membrane Separation
- ✓ Tertiary Filtration – where required
- ✓ Disinfection – where required
- ✓ Treated Water Reuse Options
Why Choose a 50 KLD STP Plant?
A 50 KLD sewage treatment system can be considered for projects generating around 50,000 litres of sewage per day, subject to detailed flow assessment and design.
50,000 L/day Treatment
Designed around a nominal treatment capacity of approximately 50,000 litres per day.
Water Reuse
Suitable tertiary treatment and disinfection can support approved non-potable treated-water reuse applications.
Technology Flexibility
ASP, MBBR, SBR and MBR configurations can be evaluated according to project conditions.
Custom Design
Tank sizing, blower capacity, pumps, diffusers and filtration are selected through project-specific design.
AMC & Maintenance
Maintenance, troubleshooting, equipment replacement and plant performance improvement services are available.
Chennai Based Support
RRR ENVIRO SYSTEMS is based in Velachery, Chennai and supports suitable projects across Tamil Nadu.
50 KLD STP Plant Technologies
The appropriate STP technology depends on wastewater characteristics, available land, treated-water quality, operating requirements and project objectives.
Activated Sludge Process
Conventional suspended-growth biological treatment using aeration and downstream solid-liquid separation.
Moving Bed Biofilm Reactor
Uses attached-growth biofilm carrier media in the biological reactor for organic matter treatment.
Sequencing Batch Reactor
Batch biological treatment with aeration and settling performed in controlled operating cycles.
Membrane Bioreactor
Combines biological treatment with membrane separation for compact and advanced treated-water applications.
50 KLD STP Treatment Process
The final process flow is selected after considering sewage quality, peak flow, reuse requirements and technology selection.
Bar Screening
Removes coarse solids and large floating materials from incoming sewage.
Collection Tank
Collects incoming sewage before further treatment and provides hydraulic buffering where required.
Equalization
Balances variations in sewage flow and loading before biological treatment where required.
Biological Treatment
Microorganisms reduce biodegradable organic matter under controlled biological conditions.
Clarification
Separates biological solids from treated water in conventional biological systems.
Tertiary Filtration
Additional filtration such as PSF and ACF can be included where required.
Disinfection
Suitable disinfection is provided according to the treated-water application.
Treated Water Tank
Treated water is stored for suitable reuse or other approved application.
50 KLD STP Plant – Technical Details
The following are general planning parameters. Final engineering values should be determined from actual wastewater characteristics and site conditions.
| Parameter | General Design Consideration |
|---|---|
| Plant Capacity | 50 KLD |
| Daily Treatment Capacity | Approximately 50,000 litres/day |
| Average Hydraulic Flow | Approximately 2.08 m³/hr over 24 hours |
| Peak Flow | To be established from actual sewage generation pattern |
| Technology | ASP / MBBR / SBR / MBR depending on project |
| Influent BOD | To be established from actual sewage characteristics |
| Influent COD | To be established from actual sewage characteristics |
| Influent TSS | To be established from actual sewage characteristics |
| Aeration | Blower and diffuser system based on oxygen requirement |
| Tertiary Treatment | PSF / ACF / UF / other suitable polishing system where required |
| Disinfection | Chlorination / UV / other suitable system |
| Tank Construction | RCC / FRP / MS / other suitable MOC according to project |
Major Equipment for 50 KLD STP Plant
Equipment sizing and configuration will be finalized according to the selected STP process.
Bar Screen
Preliminary screening equipment for removal of coarse materials from raw sewage.
Collection Tank
Receives incoming sewage and provides controlled flow to the treatment system.
Equalization Tank
Balances flow and pollutant-load variations before biological treatment where required.
Air Blowers
Provide process air for aerobic biological treatment according to calculated oxygen demand.
Fine Bubble Diffusers
Distribute air inside the aeration system and support efficient oxygen transfer.
Transfer Pumps
Transfer sewage, sludge and treated water between process stages where required.
Pressure Sand Filter
Provides additional filtration of suspended solids in suitable tertiary treatment arrangements.
Activated Carbon Filter
Provides polishing for suitable colour, odour and organic-load applications.
Disinfection System
Provides final disinfection according to reuse or discharge requirements.
Electrical Control Panel
Controls blowers, pumps and associated equipment with manual or automatic operating options.
Instrumentation
Suitable level, pressure, flow and process instruments can be provided according to project requirements.
Sludge Management
Provides arrangements for excess sludge withdrawal and appropriate sludge handling.
50 KLD STP Plant Applications
50 KLD sewage treatment systems can be considered for projects where wastewater generation is within the designed treatment capacity.
50 KLD STP Treated Water Reuse
Where the treated-water quality and applicable requirements permit, treated sewage can be considered for suitable non-potable reuse applications.
Typical applications may include gardening, landscaping, toilet flushing and other suitable utility uses, subject to the required treatment quality.
Additional tertiary treatment such as pressure filtration, activated carbon filtration, UF or other polishing systems can be considered when the reuse application requires it.
Possible Reuse Applications
- ✓ Gardening & Landscaping
- ✓ Toilet Flushing
- ✓ Green Belt Irrigation
- ✓ Suitable Utility Applications
- ✓ Process Reuse – where applicable
- ✓ Additional Polishing – if required
50 KLD STP Plant Service Areas
RRR ENVIRO SYSTEMS is based in Velachery, Chennai and supports suitable STP design, supply, installation, maintenance and upgradation requirements across Chennai and Tamil Nadu.
Treated Water Quality & Compliance
Treatment requirements depend on the final reuse or disposal application and the conditions applicable to the individual project.
A 50 KLD STP should be designed based on actual sewage generation and relevant wastewater parameters such as pH, BOD, COD, TSS and other parameters applicable to the project.
The required treatment train may include screening, equalization, biological treatment, clarification, tertiary filtration and disinfection depending on the required treated-water quality.
RRR ENVIRO SYSTEMS can support project-specific STP engineering, equipment selection, installation, commissioning, maintenance and plant upgradation.
50 KLD STP Plant in Chennai – FAQs
What is a 50 KLD STP Plant?
A 50 KLD Sewage Treatment Plant is a wastewater treatment system designed for a nominal capacity of approximately 50,000 litres of sewage per day.
What is the average flow of a 50 KLD STP?
50 KLD equals approximately 50,000 litres per day, corresponding to about 2.08 m³/hr when averaged over 24 hours. Actual design should also consider peak flow.
Which technology is suitable for a 50 KLD STP?
ASP, MBBR, SBR and MBR can be evaluated based on wastewater characteristics, available space, treated-water requirements and operational objectives.
Can treated water from a 50 KLD STP be reused?
Depending on the treatment quality and applicable requirements, treated water can be considered for suitable non-potable applications such as gardening and toilet flushing.
Does RRR ENVIRO SYSTEMS provide 50 KLD STP installation?
RRR ENVIRO SYSTEMS provides suitable project support including STP process selection, equipment supply, installation, commissioning, maintenance and upgradation.
Does RRR ENVIRO SYSTEMS provide STP AMC and service?
Yes. Maintenance, troubleshooting, equipment replacement, STP revamping and AMC support can be considered for existing treatment plants.
How can I request a quotation for a 50 KLD STP?
Contact Sales at 9710035249 or Service at 9962395875, or email rrrenviro1@gmail.com with your project location, sewage generation and application details.
Need a 50 KLD STP Plant in Chennai?
Talk to RRR ENVIRO SYSTEMS for 50 KLD sewage treatment plant requirements, technical consultation, STP equipment supply, installation, commissioning, maintenance and service support.