2000 LPH RO Plant in Chennai, Tamil Nadu
RRR ENVIRO SYSTEMS provides 2000 LPH RO Plant solutions in Chennai for commercial, institutional and suitable industrial water treatment applications.
Our 2000 LPH Reverse Osmosis systems can be designed with suitable pretreatment, high-pressure pumping, RO membrane filtration, instrumentation, electrical controls and post-treatment according to feed-water quality and application requirements.
2000 LPH RO Plant Highlights
- 💧 Nominal capacity – 2000 LPH
- 🏭 Commercial & industrial applications
- ⚙️ Customized pretreatment system
- 🧪 Chemical dosing options
- 🔵 Micron cartridge filtration
- 🚿 High-pressure RO system
- 📊 Flow & pressure monitoring
- 🎛️ Electrical control panel
- 🔧 Installation & commissioning support
- ♻️ RO service & AMC support
2000 LPH RO Plant Manufacturer & Supplier in Chennai
A 2000 LPH RO Plant is a Reverse Osmosis water-treatment system designed for a nominal permeate production capacity of approximately 2,000 litres per hour under specified design conditions.
It is suitable for customers who require a higher continuous purified-water production capacity for commercial, institutional and selected industrial applications.
RRR ENVIRO SYSTEMS designs and supplies RO Plant systems with suitable pretreatment, membrane filtration, instrumentation, controls and post-treatment based on the raw-water quality and intended application.
Important: Final membrane configuration, pump selection, recovery and pretreatment should be finalized after feed-water analysis.
Typical 2000 LPH RO Plant Includes
- ✓ Raw Water Feed Arrangement
- ✓ Raw Water / Feed Pump
- ✓ Pressure Sand / Multimedia Filter
- ✓ Activated Carbon Filter
- ✓ Antiscalant Dosing – As Required
- ✓ Micron Cartridge Filter
- ✓ High Pressure Pump
- ✓ RO Membrane Housing
- ✓ RO Membrane Elements
- ✓ Flow Meters
- ✓ Pressure Gauges
- ✓ Electrical Control Panel
- ✓ Product Water Arrangement
- ✓ Reject Water Arrangement
2000 LPH RO Plant Technical Specifications
Typical technical information is given below. Final design parameters depend on raw-water analysis, required treated-water quality and site conditions.
| RO Plant Capacity | 2000 LPH nominal permeate capacity |
|---|---|
| Technology | Reverse Osmosis (RO) |
| Application | Commercial, Institutional & Suitable Industrial Applications |
| Raw Water Source | Borewell, municipal or other suitable source water, subject to analysis |
| Pretreatment | Pressure Sand / Multimedia Filter, Activated Carbon Filter, Micron Filtration and chemical dosing as required |
| RO Membrane | Suitable membrane elements selected according to feed-water chemistry and design conditions |
| High Pressure Pump | Selected according to required membrane pressure, flow and feed-water characteristics |
| Control Panel | Suitable electrical control panel with protection, switchgear and operating controls |
| Instrumentation | Pressure gauges, flow meters and other required process instruments |
| Recovery | Final recovery determined according to feed-water quality and membrane design |
| Product Water | RO permeate suitable for intended application after required post-treatment |
| Mounting | Skid / frame-mounted configuration according to site requirements |
| Automation | Manual, semi-automatic or automatic options as per project requirements |
Major Equipment in a 2000 LPH RO Plant
Equipment selection and configuration can be customized according to water quality and application.
Raw Water Tank
Provides feed-water storage and helps maintain consistent water supply to the treatment system.
Feed Water Pump
Transfers raw water through the pretreatment and filtration stages.
Pressure Sand Filter
Reduces suspended solids, turbidity and particulate matter before RO treatment.
Activated Carbon Filter
Helps reduce chlorine, colour, odour and selected organic contaminants.
Chemical Dosing System
Antiscalant or other chemical dosing can be provided based on water chemistry.
Micron Cartridge Filter
Provides final particulate filtration before the RO membrane stage.
High Pressure Pump
Generates the pressure required for the selected RO membrane configuration.
RO Membrane System
Uses pressure-driven membrane separation to reduce dissolved salts and contaminants.
Flow Meters
Monitor feed, permeate and concentrate flows as required.
Pressure Gauges
Monitor important pressure conditions throughout the RO system.
Electrical Control Panel
Provides equipment control, switching and electrical protection.
Reject Water Arrangement
RO concentrate management can be designed according to site and application requirements.
2000 LPH RO Plant Water Treatment Process
The typical treatment process combines pretreatment, chemical conditioning and Reverse Osmosis membrane filtration.
Raw Water Feed
Raw water enters the feed-water tank or direct supply arrangement.
Feed Pumping
Feed water is pumped towards the pretreatment system.
Sand Filtration
Pressure sand or multimedia filtration reduces suspended solids and turbidity.
Carbon Filtration
Activated carbon filtration helps reduce chlorine and selected organic contaminants.
Chemical Conditioning
Antiscalant or other conditioning can be provided according to feed-water chemistry.
Micron Filtration
Cartridge filtration provides additional membrane protection.
High Pressure Pump
The pump provides the pressure required for the RO membrane system.
RO Membrane Separation
The RO membrane produces permeate and concentrate streams.
2000 LPH RO Plant Applications
A 2000 LPH RO Plant can be considered for a variety of commercial, institutional and selected industrial water-treatment requirements.
Benefits of a 2000 LPH RO Plant
Higher Water Production
Provides approximately 2,000 litres per hour nominal permeate capacity under specified design conditions.
Wide Application Range
Suitable for commercial, institutional and selected industrial water-treatment applications.
Customized Engineering
Pump, membrane, pretreatment and controls can be selected according to project requirements.
Membrane Protection
Proper pretreatment helps reduce fouling, scaling and chlorine-related membrane risks.
Skid Mounted Option
The system can be arranged on a suitable skid or structural frame for installation.
Service Support
Maintenance, membrane replacement, media replacement and AMC support can be provided.
2000 LPH RO Plant Installation & Service in Chennai
RRR ENVIRO SYSTEMS provides suitable installation, commissioning, maintenance and service support for RO systems in Chennai and surrounding areas.
Installation
Mechanical, piping and electrical installation support according to project scope.
Commissioning
Startup inspection and operating parameter verification during commissioning.
RO Membrane Replacement
Membrane inspection and replacement support when required.
Membrane Cleaning
Cleaning service and recommendations based on membrane fouling conditions.
RO Plant Repair
Troubleshooting support for pumps, controls, instruments and suitable RO equipment.
AMC & Preventive Maintenance
Periodic inspection and preventive maintenance support for suitable RO installations.
2000 LPH RO Plant Supplier in Chennai, Tamil Nadu
RRR ENVIRO SYSTEMS is based in Velachery, Chennai, and provides suitable RO Plant solutions for customers across Chennai and Tamil Nadu.
Need a 2000 LPH RO Plant in Chennai?
Send your raw-water test report and application details to get a suitable technical proposal and quotation.
RRR ENVIRO SYSTEMS
📍 Office Address
No. 7, 11th Cross Street,
Dhandeeswaram,
Velachery, Chennai – 600042
✉ Email
rrrenviro1@gmail.com
2000 LPH RO Plant in Chennai – Frequently Asked Questions
What is a 2000 LPH RO Plant?
A 2000 LPH RO Plant is a Reverse Osmosis water-treatment system designed for a nominal permeate production capacity of approximately 2,000 litres per hour under specified design conditions.
Who can use a 2000 LPH RO Plant?
It may be suitable for hotels, restaurants, hospitals, schools, colleges, apartments, commercial buildings, laboratories and selected industrial applications.
Do you supply 2000 LPH RO Plants in Chennai?
RRR ENVIRO SYSTEMS provides suitable 2000 LPH RO Plant solutions for customers in Chennai and Tamil Nadu, subject to raw-water quality and application requirements.
What pretreatment is required before RO?
Depending on feed-water quality, pretreatment may include pressure sand or multimedia filtration, activated carbon filtration, chemical dosing and micron cartridge filtration. Final selection should be based on water analysis.
Can the 2000 LPH RO Plant be customized?
Yes. Pretreatment, membrane configuration, pump, instrumentation, automation and post-treatment can be selected according to feed-water characteristics and required treated-water quality.
Do you provide RO Plant installation?
Installation and commissioning support can be provided for supplied RO systems according to the agreed project scope.
Do you provide RO membrane replacement and service?
Yes. RO membrane inspection, cleaning recommendations, replacement and suitable maintenance support are available.
How can I get a quotation?
Contact Sales at 9710035249, Service at 9962395875, Admin at 8939126848 or email rrrenviro1@gmail.com.
2000 LPH RO Plant Manufacturer & Supplier in Chennai
Contact RRR ENVIRO SYSTEMS for 2000 LPH RO Plant supply, installation, commissioning, service, membrane replacement and AMC support.