100 KLD STP Plant in Chennai
RRR ENVIRO SYSTEMS provides 100 KLD Sewage Treatment Plant solutions for residential, commercial, institutional, hospitality and suitable wastewater treatment applications in Chennai, Tamil Nadu.
Our support includes STP process selection, engineering, equipment supply, installation, commissioning, maintenance, AMC and plant upgradation according to project requirements.
100 KLD STP – Quick Information
- Nominal Capacity: 100 KLD
- Approx. Treatment: 100,000 L/day
- Average Flow: approx. 4.17 m³/hr
- Domestic Sewage Treatment
- Primary Treatment
- Biological Treatment
- Secondary Separation
- Tertiary Treatment Options
- Disinfection & Reuse Options
100 KLD Sewage Treatment Plant in Chennai
A 100 KLD STP Plant in Chennai is designed for a nominal sewage treatment capacity of approximately 100,000 litres per day.
When averaged over 24 hours, 100 KLD corresponds to approximately 4.17 m³/hr. Actual hydraulic design should consider peak flow, operating hours, sewage generation pattern and site conditions.
RRR ENVIRO SYSTEMS provides project-specific sewage treatment solutions for suitable requirements across Chennai and Tamil Nadu.
100 KLD STP Basic Details
- ✓ Nominal Capacity – 100 KLD
- ✓ Daily Treatment – 100,000 Litres/Day
- ✓ Average Flow – approx. 4.17 m³/hr
- ✓ Screening & Preliminary Treatment
- ✓ Biological Treatment
- ✓ Clarification / Membrane Separation
- ✓ Tertiary Filtration – where required
- ✓ Disinfection – where required
- ✓ Treated Water Reuse Options
Why Choose a 100 KLD STP Plant?
A 100 KLD sewage treatment system can be considered for projects generating around 100,000 litres of sewage per day, subject to detailed flow and wastewater assessment.
100,000 L/day Capacity
Designed around a nominal sewage treatment capacity of approximately 100,000 litres per day.
Water Reuse
Suitable tertiary treatment and disinfection can support approved non-potable treated-water reuse applications.
Technology Options
ASP, MBBR, SBR and MBR technologies can be evaluated according to project requirements.
Project-Specific Design
Tank sizing, pumps, blowers, diffusers and filtration are selected according to the actual project design.
Service & AMC
STP maintenance, troubleshooting, equipment replacement, AMC and plant improvement services can be provided.
Chennai Based Support
RRR ENVIRO SYSTEMS is based in Velachery, Chennai and supports suitable projects across Tamil Nadu.
100 KLD STP Plant Technologies
The appropriate technology depends on sewage characteristics, available land, treated-water quality, operating requirements and project objectives.
Activated Sludge Process
Conventional suspended-growth biological treatment using aeration and downstream solid-liquid separation.
Moving Bed Biofilm Reactor
Attached-growth biological treatment using biofilm carrier media inside the biological reactor.
Sequencing Batch Reactor
Batch biological treatment using controlled aeration, settling and decanting cycles.
Membrane Bioreactor
Combines biological treatment with membrane separation for compact and advanced treated-water applications.
100 KLD STP Treatment Process
The final process flow is selected after evaluating sewage quality, peak flow, reuse requirements and selected technology.
Bar Screening
Removes coarse solids and larger floating materials from incoming sewage.
Collection Tank
Receives sewage and provides controlled flow to the subsequent treatment stages.
Equalization
Balances variations in flow and pollutant loading where equalization is required.
Biological Treatment
Microorganisms reduce biodegradable organic matter under controlled biological conditions.
Clarification
Separates biological solids from treated water in conventional biological treatment systems.
Tertiary Filtration
PSF, ACF, UF or other suitable polishing systems may be provided according to requirements.
Disinfection
Suitable disinfection is provided according to the treated-water application.
Treated Water Tank
Treated water is stored for suitable reuse or other approved application.
100 KLD STP Plant – Technical Details
The following parameters are general planning information. Final engineering values should be determined from actual wastewater characteristics and site conditions.
| Parameter | General Design Consideration |
|---|---|
| Plant Capacity | 100 KLD |
| Daily Treatment Capacity | Approximately 100,000 litres/day |
| Average Hydraulic Flow | Approximately 4.17 m³/hr over 24 hours |
| Peak Flow | To be established from actual sewage generation pattern |
| Technology | ASP / MBBR / SBR / MBR depending on project |
| Influent BOD | To be established from actual sewage characteristics |
| Influent COD | To be established from actual sewage characteristics |
| Influent TSS | To be established from actual sewage characteristics |
| Aeration | Blower and diffuser system based on calculated oxygen requirement |
| Tertiary Treatment | PSF / ACF / UF / other suitable polishing system where required |
| Disinfection | Chlorination / UV / other suitable system |
| Tank Construction | RCC / FRP / MS / other suitable MOC according to project |
Major Equipment for 100 KLD STP Plant
Equipment sizing and configuration will be finalized according to the selected treatment process and project requirements.
Bar Screen
Preliminary screening equipment for removal of coarse materials from raw sewage.
Collection Tank
Receives incoming sewage and provides controlled flow to the treatment system.
Equalization Tank
Balances flow and pollutant-load variations before biological treatment where required.
Air Blowers
Provide process air for aerobic biological treatment based on calculated oxygen demand.
Fine Bubble Diffusers
Distribute air inside the aeration system and support efficient oxygen transfer.
Transfer Pumps
Transfer sewage, sludge and treated water between process stages where required.
Pressure Sand Filter
Provides additional filtration in suitable tertiary treatment arrangements.
Activated Carbon Filter
Provides polishing for suitable colour, odour and organic load applications.
Disinfection System
Provides final disinfection according to treated-water reuse or disposal requirements.
Electrical Control Panel
Controls blowers, pumps and associated equipment with manual or automatic operation.
Instrumentation
Suitable level, pressure, flow and process instruments can be included according to project requirements.
Sludge Management
Provides arrangements for excess sludge withdrawal and appropriate sludge handling.
100 KLD STP Plant Applications
100 KLD sewage treatment systems can be considered for projects where wastewater generation is within the designed treatment capacity.
100 KLD STP Treated Water Reuse
Where treated-water quality and applicable requirements permit, treated sewage can be considered for suitable non-potable reuse applications.
Typical applications may include gardening, landscaping, toilet flushing and other suitable utility uses, subject to the required treatment quality.
Additional tertiary treatment such as pressure filtration, activated carbon filtration, UF or other polishing systems can be considered where required by the reuse application.
Possible Reuse Applications
- ✓ Gardening & Landscaping
- ✓ Toilet Flushing
- ✓ Green Belt Irrigation
- ✓ Suitable Utility Applications
- ✓ Process Reuse – where applicable
- ✓ Additional Polishing – if required
100 KLD STP Plant Service Areas
RRR ENVIRO SYSTEMS is based in Velachery, Chennai and supports suitable STP design, supply, installation, maintenance and upgradation requirements across Chennai and Tamil Nadu.
Treated Water Quality & Compliance
Treatment requirements depend on the final reuse or disposal application and applicable project conditions.
A 100 KLD STP should be designed based on actual sewage generation and relevant wastewater parameters such as pH, BOD, COD, TSS and other parameters applicable to the project.
The required treatment train may include screening, equalization, biological treatment, clarification, tertiary filtration and disinfection depending on the required treated-water quality.
RRR ENVIRO SYSTEMS can support project-specific STP engineering, equipment selection, installation, commissioning, maintenance and plant upgradation.
100 KLD STP Plant in Chennai – FAQs
What is a 100 KLD STP Plant?
A 100 KLD Sewage Treatment Plant is a wastewater treatment system designed for a nominal capacity of approximately 100,000 litres of sewage per day.
What is the average flow of a 100 KLD STP?
100 KLD equals approximately 100,000 litres per day, corresponding to about 4.17 m³/hr when averaged over 24 hours. Actual design should also consider peak flow.
Which technology is suitable for a 100 KLD STP?
ASP, MBBR, SBR and MBR technologies can be evaluated according to wastewater characteristics, available land, treated-water requirements and operational objectives.
Can treated water from a 100 KLD STP be reused?
Depending on the treatment quality and applicable requirements, treated water can be considered for suitable non-potable applications such as gardening and toilet flushing.
Does RRR ENVIRO SYSTEMS provide 100 KLD STP installation?
RRR ENVIRO SYSTEMS provides suitable project support including STP process selection, equipment supply, installation, commissioning, maintenance and upgradation.
Does RRR ENVIRO SYSTEMS provide STP AMC and service?
Maintenance, troubleshooting, equipment replacement, STP revamping and AMC support can be considered for existing treatment plants.
How can I request a quotation for a 100 KLD STP?
Contact Sales at 9710035249 or Service at 9962395875, or email rrrenviro1@gmail.com with your project location, sewage generation and application details.
Need a 100 KLD STP Plant in Chennai?
Talk to RRR ENVIRO SYSTEMS for 100 KLD sewage treatment plant requirements, technical consultation, STP equipment supply, installation, commissioning, maintenance and service support.