SEWAGE TREATMENT PLANT • 50 KLD

50 KLD STP Plant in Chennai

RRR ENVIRO SYSTEMS provides 50 KLD Sewage Treatment Plant solutions for residential, commercial, institutional, hospitality and other suitable wastewater treatment applications in Chennai, Tamil Nadu.

We support STP process selection, engineering, equipment supply, installation, commissioning, maintenance and upgradation according to project requirements.

50 KLD STP – Quick Information

  • Nominal Capacity: 50 KLD
  • Approx. Treatment: 50,000 L/day
  • Average Flow: approx. 2.08 m³/hr
  • Domestic Sewage Treatment
  • Primary & Biological Treatment
  • Secondary Solid Separation
  • Tertiary Treatment Options
  • Disinfection & Reuse Options
50 KLD SEWAGE TREATMENT PLANT

50 KLD Sewage Treatment Plant in Chennai

A 50 KLD STP Plant in Chennai is designed for a nominal sewage treatment capacity of approximately 50,000 litres per day.

The average flow corresponding to 50 KLD is approximately 2.08 m³/hr when averaged over 24 hours. Actual hydraulic design must also consider peak flow, infiltration, operating hours and site-specific sewage generation.

RRR ENVIRO SYSTEMS provides project-specific sewage treatment solutions for suitable requirements across Chennai and Tamil Nadu.

50 KLD STP Basic Details

  • ✓ Nominal Capacity – 50 KLD
  • ✓ Daily Flow – 50,000 Litres/Day
  • ✓ Average Flow – approx. 2.08 m³/hr
  • ✓ Screening & Preliminary Treatment
  • ✓ Biological Treatment
  • ✓ Clarification / Membrane Separation
  • ✓ Tertiary Filtration – where required
  • ✓ Disinfection – where required
  • ✓ Treated Water Reuse Options
50 KLD STP SOLUTION

Why Choose a 50 KLD STP Plant?

A 50 KLD sewage treatment system can be considered for projects generating around 50,000 litres of sewage per day, subject to detailed flow assessment and design.

💧

50,000 L/day Treatment

Designed around a nominal treatment capacity of approximately 50,000 litres per day.

🌱

Water Reuse

Suitable tertiary treatment and disinfection can support approved non-potable treated-water reuse applications.

⚙️

Technology Flexibility

ASP, MBBR, SBR and MBR configurations can be evaluated according to project conditions.

📐

Custom Design

Tank sizing, blower capacity, pumps, diffusers and filtration are selected through project-specific design.

🔧

AMC & Maintenance

Maintenance, troubleshooting, equipment replacement and plant performance improvement services are available.

📍

Chennai Based Support

RRR ENVIRO SYSTEMS is based in Velachery, Chennai and supports suitable projects across Tamil Nadu.

STP TECHNOLOGY OPTIONS

50 KLD STP Plant Technologies

The appropriate STP technology depends on wastewater characteristics, available land, treated-water quality, operating requirements and project objectives.

ASP

Activated Sludge Process

Conventional suspended-growth biological treatment using aeration and downstream solid-liquid separation.

MBBR

Moving Bed Biofilm Reactor

Uses attached-growth biofilm carrier media in the biological reactor for organic matter treatment.

SBR

Sequencing Batch Reactor

Batch biological treatment with aeration and settling performed in controlled operating cycles.

MBR

Membrane Bioreactor

Combines biological treatment with membrane separation for compact and advanced treated-water applications.

TYPICAL PROCESS FLOW

50 KLD STP Treatment Process

The final process flow is selected after considering sewage quality, peak flow, reuse requirements and technology selection.

1

Bar Screening

Removes coarse solids and large floating materials from incoming sewage.

2

Collection Tank

Collects incoming sewage before further treatment and provides hydraulic buffering where required.

3

Equalization

Balances variations in sewage flow and loading before biological treatment where required.

4

Biological Treatment

Microorganisms reduce biodegradable organic matter under controlled biological conditions.

5

Clarification

Separates biological solids from treated water in conventional biological systems.

6

Tertiary Filtration

Additional filtration such as PSF and ACF can be included where required.

7

Disinfection

Suitable disinfection is provided according to the treated-water application.

8

Treated Water Tank

Treated water is stored for suitable reuse or other approved application.

ENGINEERING DATA

50 KLD STP Plant – Technical Details

The following are general planning parameters. Final engineering values should be determined from actual wastewater characteristics and site conditions.

Parameter General Design Consideration
Plant Capacity 50 KLD
Daily Treatment Capacity Approximately 50,000 litres/day
Average Hydraulic Flow Approximately 2.08 m³/hr over 24 hours
Peak Flow To be established from actual sewage generation pattern
Technology ASP / MBBR / SBR / MBR depending on project
Influent BOD To be established from actual sewage characteristics
Influent COD To be established from actual sewage characteristics
Influent TSS To be established from actual sewage characteristics
Aeration Blower and diffuser system based on oxygen requirement
Tertiary Treatment PSF / ACF / UF / other suitable polishing system where required
Disinfection Chlorination / UV / other suitable system
Tank Construction RCC / FRP / MS / other suitable MOC according to project
STP EQUIPMENT

Major Equipment for 50 KLD STP Plant

Equipment sizing and configuration will be finalized according to the selected STP process.

🛡️

Bar Screen

Preliminary screening equipment for removal of coarse materials from raw sewage.

🌊

Collection Tank

Receives incoming sewage and provides controlled flow to the treatment system.

⚖️

Equalization Tank

Balances flow and pollutant-load variations before biological treatment where required.

💨

Air Blowers

Provide process air for aerobic biological treatment according to calculated oxygen demand.

🔵

Fine Bubble Diffusers

Distribute air inside the aeration system and support efficient oxygen transfer.

⚙️

Transfer Pumps

Transfer sewage, sludge and treated water between process stages where required.

🪨

Pressure Sand Filter

Provides additional filtration of suspended solids in suitable tertiary treatment arrangements.

🌿

Activated Carbon Filter

Provides polishing for suitable colour, odour and organic-load applications.

🧪

Disinfection System

Provides final disinfection according to reuse or discharge requirements.

🔄

Electrical Control Panel

Controls blowers, pumps and associated equipment with manual or automatic operating options.

📊

Instrumentation

Suitable level, pressure, flow and process instruments can be provided according to project requirements.

♻️

Sludge Management

Provides arrangements for excess sludge withdrawal and appropriate sludge handling.

APPLICATIONS

50 KLD STP Plant Applications

50 KLD sewage treatment systems can be considered for projects where wastewater generation is within the designed treatment capacity.

Apartment Complexes
Residential Communities
Hotels & Resorts
Hospitals
Schools
Colleges
Hostels
Office Buildings
Commercial Complexes
Restaurants
Institutions
Industrial Campuses
TREATED WATER REUSE

50 KLD STP Treated Water Reuse

Where the treated-water quality and applicable requirements permit, treated sewage can be considered for suitable non-potable reuse applications.

Typical applications may include gardening, landscaping, toilet flushing and other suitable utility uses, subject to the required treatment quality.

Additional tertiary treatment such as pressure filtration, activated carbon filtration, UF or other polishing systems can be considered when the reuse application requires it.

Possible Reuse Applications

  • ✓ Gardening & Landscaping
  • ✓ Toilet Flushing
  • ✓ Green Belt Irrigation
  • ✓ Suitable Utility Applications
  • ✓ Process Reuse – where applicable
  • ✓ Additional Polishing – if required
CHENNAI • TAMIL NADU

50 KLD STP Plant Service Areas

RRR ENVIRO SYSTEMS is based in Velachery, Chennai and supports suitable STP design, supply, installation, maintenance and upgradation requirements across Chennai and Tamil Nadu.

Velachery
Guindy
Adyar
Taramani
Perungudi
Pallikaranai
Sholinganallur
OMR
Tambaram
Porur
Ambattur
Sriperumbudur
STP PERFORMANCE

Treated Water Quality & Compliance

Treatment requirements depend on the final reuse or disposal application and the conditions applicable to the individual project.

A 50 KLD STP should be designed based on actual sewage generation and relevant wastewater parameters such as pH, BOD, COD, TSS and other parameters applicable to the project.

The required treatment train may include screening, equalization, biological treatment, clarification, tertiary filtration and disinfection depending on the required treated-water quality.

RRR ENVIRO SYSTEMS can support project-specific STP engineering, equipment selection, installation, commissioning, maintenance and plant upgradation.

FREQUENTLY ASKED QUESTIONS

50 KLD STP Plant in Chennai – FAQs

What is a 50 KLD STP Plant?

A 50 KLD Sewage Treatment Plant is a wastewater treatment system designed for a nominal capacity of approximately 50,000 litres of sewage per day.

What is the average flow of a 50 KLD STP?

50 KLD equals approximately 50,000 litres per day, corresponding to about 2.08 m³/hr when averaged over 24 hours. Actual design should also consider peak flow.

Which technology is suitable for a 50 KLD STP?

ASP, MBBR, SBR and MBR can be evaluated based on wastewater characteristics, available space, treated-water requirements and operational objectives.

Can treated water from a 50 KLD STP be reused?

Depending on the treatment quality and applicable requirements, treated water can be considered for suitable non-potable applications such as gardening and toilet flushing.

Does RRR ENVIRO SYSTEMS provide 50 KLD STP installation?

RRR ENVIRO SYSTEMS provides suitable project support including STP process selection, equipment supply, installation, commissioning, maintenance and upgradation.

Does RRR ENVIRO SYSTEMS provide STP AMC and service?

Yes. Maintenance, troubleshooting, equipment replacement, STP revamping and AMC support can be considered for existing treatment plants.

How can I request a quotation for a 50 KLD STP?

Contact Sales at 9710035249 or Service at 9962395875, or email rrrenviro1@gmail.com with your project location, sewage generation and application details.

Need a 50 KLD STP Plant in Chennai?

Talk to RRR ENVIRO SYSTEMS for 50 KLD sewage treatment plant requirements, technical consultation, STP equipment supply, installation, commissioning, maintenance and service support.